Sampling using a valve fitted with a heating jacket
The heating jacket on a sampling valve is used to heat the fluid or maintain its temperature during sampling.
The ECB sampling valve without flange, specifically designed for horizontal lines, offers a practical and safe solution for representative sampling of temperature-sensitive chemicals, without disrupting manufacturing processes. The ECB's integrated heating jacket guarantees sampling at a constant temperature, prevents solidification of the sampled liquids, and maintains their viscosity while preserving the integrity of the production line. The wafer design without flange reduces pressure losses and space requirements. Initially manufactured in stainless steel, this BIAR sampler is also available in Hastelloy. Its unique quick connection system means that a variety of bottles and accessories can be used without having to replace the sampling system, simplifying management, and reducing costs. The ECB sampling system, also known as PRISEMASSON®, is based on a modular concept, enabling it to be adapted to different requirements and needs, whether in terms of materials, sealing or actuators.
Illustrative drawing of a standard ECB sampling valve, without additional options, featuring the VMB magic wheel actuator type
| NrArticle | DN | h1 | h2 | l1 | d1 | D | k | nxd | Kg |
|---|---|---|---|---|---|---|---|---|---|
| xxxxxx | 25 | 60.5 | 113 | 178.5 | 36 | 145 | 85 | 4X14 | 10.4 |
| xxxxxx | 50 | 85.5 | 126 | 183.8 | 62 | 189 | 125 | 4X18 | 15.1 |
| xxxxxx | 80 | 103 | 140 | 203 | 90 | 220 | 160 | 8(x)4x18 | 17.5 |
| xxxxxx | 100 | 120.5 | 153 | 216.5 | 116 | 254 | 180 | 8x18 | 20.8 |
| NrArticle | DN | h1 | h2 | l1 | d1 | D | k | nxd | Kg |
|---|---|---|---|---|---|---|---|---|---|
| 05198400 | 25 | 60.5 | 113 | 178.5 | 36 | 145 | 85 | 4X14 | 10.4 |
| xxxxxx | 50 | 85.5 | 126 | 183.8 | 62 | 189 | 125 | 4X18 | 15.1 |
| 02977600 | 80 | 103 | 140 | 203 | 90 | 220 | 160 | 8x18 | 17.5 |
| xxxxxx | 100 | 120.5 | 153 | 216.5 | 116 | 254 | 190 | 8x22 | 20.8 |
| NrArticle | NPS | h1 | h2 | l1 | d1 | D | k | nxd | Kg |
|---|---|---|---|---|---|---|---|---|---|
| xxxxxx | 1 | 60.5 | 113 | (i) | 36 | 145 | 79.4 | 4x15.9 | 10.6 |
| xxxxxx | 2 | 85.5 | 126 | (i) | 62 | 189 | 120.6 | 4x19 | 14.7 |
| xxxxxx | 3 | 103 | 140 | (i) | 90 | 254 | 152.4 | 4x19 | 17.6 |
| xxxxxx | 4 | 120.5 | 153 | (i) | 116 | 302 | 190.5 | 8x19 | 21.1 |
| NrArticle | NPS | h1 | h2 | l1 | d1 | D | k | nxd | Kg |
|---|---|---|---|---|---|---|---|---|---|
| xxxxxx | 1 | 60,5 | 113 | (i) | 36 | 145 | 79.4 | 4x15.9 | 10.6 |
| xxxxxx | 2 | 85,5 | 126 | (i) | 62 | 189 | 120.6 | 4x19 | 14.7 |
| xxxxxx | 3 | 103 | 140 | (i) | 90 | 254 | 168.3 | 8x22.2 | 17.6 |
| xxxxxx | 4 | 120.5 | 153 | (i) | 116 | 302 | 200 | 8x22.2 | 21.1 |
| °C | 20° | 100° | 150° | 200° | |
|---|---|---|---|---|---|
| Vanne (Pression max.) bar | 16 | 15.1 | 13.7 | 12.7 | |
| Enveloppe chauffante (pression max.) bar | 16 | 15.1 | 13.7 | 12.7 |
| °C | 20° | 100° | 150° | 200° | |
|---|---|---|---|---|---|
| Vanne (Pression max.) bar | 16 | 16 | 16 | 16 | |
| Enveloppe chauffante (pression max.) bar | 40 | 37.9 | 34.4 | 31.8 |
| °F / (°C) | <100° (<40°) | 200° (100°) | 300° (150°) | 400° (200°) |
|---|---|---|---|---|
| Vanne (Pression max.) psi (bar) | 217.6 (15.9) | 188.5 (13.3) | 174 (12) | 159.5 (11.2) |
| Enveloppe chauffante (pression max.) psi (bar) | 217.6 (15.9) | 188.5 (13.3) | 174 (12) | 159.5 (11.2) |
| °C | <100° (<40°) | 200° (100°) | 300° (150°) | 400° (200°) |
|---|---|---|---|---|
| Vanne (Pression max.) psi(bar) | 232.1 (16) | 232.1 (16) | 232.1 (16) | 232.1 (16) |
| Enveloppe chauffante (pression max.) psi (bar) | 594.7 (41.4) | 493.1 (34.8) | 449.6 (31.4) | 420.6 (29.2) |
Each ECB Inline sampling valve can be configured according to production specifications and sampling parameters.
The ECB sampling valves can be equipped with various types of sealing
In its standard version, the ECB sampling valves is made from stainless steel. It is also available in Hastelloy®
ECB sampling valves can be configured with different drives
The venting hole fitted to each ECB sampling valve prevents overpressure and explosions.
It can be connected in different ways
The vent hole in our sampling systems prevents overpressure in the container and allows for the recovery of toxic gases.
If bottle rinsing is required, the ECB samplers can be configured with the nitrogen flushing option
If bottle rinsing is required, the ECB samplers can be configured with the nitrogen flushing option
The heating jacket on a sampling valve is used to heat the fluid or maintain its temperature during sampling.
ECB In-line sampling valves are compatible with a wide range of accessories
BIAR SA offers inline sampling valves that can be adapted to your sampling and production constraints