EB

  • Inline sampling valve
  • Wafer type
  • Horizontal assembly
  • Multifonction
Material 1.4404 / 316L PTFE
Pressures PN 16 / 40 ANSI 150# / 300#
Temperatures -40°C / 200°C -40°F / 392°F

Designed for horizontal or vertical assembly, the EB sampling valve without flange (wafer type) offers a reliable and practical solution for representative sampling without interrupting production processes. Initially manufactured in stainless steel with a PTFE seal, it is also available in other alloys and seals, depending on specific requirements. In chemical and petrochemical plants, the EB valve ensures safety when sampling hazardous and toxic liquids such as halogens, Grignard reagents, alkylating agents and concentrated acids. The wafer design (without flange) reduces pressure losses and space requirements. Its unique bayonet connection system for receptacles means that different accessories can be used without changing the sampling system, simplifying management while keeping costs under control. Based on a modular concept, the EB sampling system, also known as PRISEMASSON®, can be adapted to suit different requirements and needs (materials, sealing, actuators).

TECHNICAL DETAILS OF AN EB INLINE SAMPLING VALVE

Illustrative diagram of a standard EB sampling valve, without additional options, featuring the VMB magic wheel actuator type

Dimensions in mm
Your specificities
Standard
  • DIN
  • ANSI
Class
  • 16
  • 40
  • 150
  • 300
NrArticle DN h1 h2 d1 d2 D k nxd Kg
xxxxxxxx 15 50.5 107 24 20 129 65 4x14 7.2
xxxxxxxx 25 60.5 113 36 26 145 85 4x14 8.6
xxxxxxxx 40 78 120 50 26 175 110 4x18 9.8
xxxxxxxx 50 85.5 126 62 26 189 125 4x18 13.1
00735502 80 103 140 90 26 220 160 8x18 15.5
00923602 100 120.5 153 116 26 254 180 8x18 18.8
NrArticle DN h1 h2 d1 d2 D k nxd Kg
01491900 15 50.5 107 24 20 129 65 4x14 7.2
01678501 25 60.5 113 36 26 145 85 4x14 8.6
00735300 40 78 120 50 26 175 110 4x18 9.8
01678701 50 85.5 126 62 26 189 125 4x18 13.1
02008600 80 103 140 90 26 220 160 8x18 15.5
xxxxxxxx 100 120.5 153 116 26 254 190 8x22 18.8
NrArticle NPS h1 h2 d1 d2 D k nxd Kg
01198400 3/4 54.3 110 24 26 135 69.9 4x15.7 8.5
01201502 1 60.5 113 36 26 145 79.2 4x15.7 9.1
01201601 1 1/2 78 120 50 26 175 98.6 4x15.7 11.8
01108204 2 85.5 126 62 26 189 120.7 4x19.1 12.9
01082200 2 1/2 95.5 134 78 26 220 139.7 4x19.1 13.6
01082103 3 103 140 90 26 254 152.4 4x19.1 15.8
01283002 4 120.5 153 116 26 302 190.5 8x19.1 19.1
NrArticle NPS h1 h2 d1 d2 D k nxd Kg
xxxxxxxx 3/4 54.3 110 24 26 135 82.6 4x19.1 8.5
xxxxxxxx 1 60.5 113 36 26 145 88.9 4x19.1 9.1
xxxxxxxx 1 1/2 78 120 50 26 175 114.3 4x22.4 11.8
02223700 2 85.5 126 62 26 189 127 8x19.1 12.9
xxxxxxxx 2 1/2 95.5 134 78 26 220 149.4 8x22.4 13.6
02223601 3 103 140 90 26 254 168.1 8x22.4 15.8
xxxxxxxx 4 120.5 153 116 26 302 200.2 8x22.4 19.1
Pressures and temperatures
°C -40 0 100 150 200
PN16 16 16 15.1 13.7 12.7
°C -40 0 100 150 200
PN40 16 16 16 16 16
°F (°C) -20 (-29) 0 (-18) 200 (94) 300 (149) 400 (205)
150# psi (bar) 232 (16) 232 (16) 195 (14) 175 (12) 160 (11)
°F (°C) -20 (-29) 0 (-18) 200 (94) 300 (149) 400 (205)
300# psi (bar) 232 (16) 232 (16) 232 (16) 232 (16) 232 (16)

Each EB Inline sampling valve can be configured according to production specifications and sampling parameters.

Different sealings available

The EB sampling valves can be equipped with various types of sealing

image-0

Standard Stem Gasket

image-0

Simple stuffing box

image-0

Double Stuffing Box

image-0

HP Stem Gasket

image-0

Bellows Seal

image-0

Stellite Stem Gasket

Different materials

In its standard version, the LLB sampling valves is made from stainless steel. It is also available in various other alloys.

1.4404 / 316L 2.4602 / C22 1.4460-62 / Duplex Zirconium Tantalum Titanium

ACTUATOR OPTIONS FOR THE EB SAMPLING SYSTEM

EB sampling valves can be configured with different drives

image-0

Magic Hand Wheel - VMB

image-0

Pneumatic actuator - CPB

image-0

Spring to Close hand lever - RPS

image-0

Manual handwheel - CVS

image-0

Cooling fins

VENT HOLE PRINCIPLE

The venting hole fitted to each LLB sampling valve prevents overpressure and explosions.

It can be connected in different ways

Vent hole principle

The vent hole in our sampling systems prevents overpressure in the container and allows for the recovery of toxic gases.

NITROGEN RINSING THROUGH THE SPINDLE

If bottle rinsing is required, the LLB samplers can be configured with the nitrogen flushing option

NITROGEN RINSING THROUGH THE SPINDLE

If bottle rinsing is required, the ECB samplers can be configured with the nitrogen flushing option

ACCESSORIES DESIGNED FOR THE EB INLINE SAMPLING VALVES

EB Inline samplers are compatible with a wide range of accessories

FAY adapter

Adaptateur - FAY

Bottles

bottle

Safety cabinets

Safety cabinets

Revo cabinet RAI

Revo cabinet - RAI

Stainless steel or alloys container LY

Containers

Inline sampling valves

BIAR SA offers inline sampling valves that can be adapted to your sampling and production constraints

STAINLESS STEEL

MLB
  • Inline sampling valve
  • With flanges
  • Horizontal assembly
  • Multifunctional
EB
  • Inline sampling valve
  • Wafer type
  • Horizontal assembly
  • Multifonction
VLB
  • Inline sampling valve 
  • With flanges
  • Vertical assembly
  • Multifunction
LLB
  • Inline sampling valve
  • With flanges
  • Lateral assembly
  • Multifonction

HEATING JACKET

MLB‐EC
  • Inline sampling valve with heating jacket
  • With flanges
  • Horizontal assembly
  • Multifunctional
ECB
  • Inline sampling valve with heating jacket
  • Wafer type
  • Horizontal assembly
  • Multifonctional
VLB‐EC
  • Inline sampling valve with heating jacket
  • With flanges
  • Vertical assembly
  • Multifonctional
LLB‐EC
  • Inline sampling valve with heating jacket
  • With flanges
  • Lateral assembly
  • Multifonctional

PFA

PLI
  • PFA lined Inline sampling valve
  • With flanges
  • Horizontal assembly
  • Multifonctional
EBP
  • PFA lined Inline sampling valve
  • Wafer type
  • Horizontal assembly
  • Multifonctional