"Safety, efficiency, simplicity"
BIAR SAMPLING SYSTEMS
BIAR Sampling Systems significantly help preserving the environment.
Inline and reactor sampling systems for liquid and gas
Inline and reactor sampling systems for liquid and gas
To take a liquid sulphur sample
Problem / customer requirement:
  • To take a liquid sulphur sample at 130°C which solidifies at 80°C
  • To neutralize the toxic fumes
  • To obtain a representative sample of a highly viscous solution
BIAR's solution:
    The PFA conical cup. It allows to:
  • take a visual sample at temperatures up to 320°C
  • take a quantitative sample at temperatures up to 220°C
  • Be unbreakable
  • Control the quantity of sample (translucent)
  • Un-mold the sample in a simple manner
Disadvantages with other means:
    Bottle :
  • Can break when sample solidifies

    Piston-injector and container :
  • Must be re-heated to extract the sample
Other possible applications:
  • anthracene
  • tar
  • liquid with solids