"Safety, efficiency, simplicity"
BIAR SAMPLING SYSTEMS
BIAR Sampling Systems significantly help preserving the environment.
Inline and reactor sampling systems for liquid and gas
Inline and reactor sampling systems for liquid and gas
BIAR: ACTIFLOW® Reactor Sampling System request for quotation form

Please fill the form below with as much details as possible and one of our consultant will either contact you if more information is needed or send you a quotation as soon as possible.

The 4 fields marked with a star (*) are mandatory.


Contact details
*Company: Department: *Contact:
Street: Zip Code / City: State:
*Phone: Extension: Date:
Fax: *Email: BIAR:

ACTIFLOW®, is a new sampling device with a magnetically activated piston to take a sample of a liquid content from a reactor or storage tank. This device is specially designed for sampling under difficult conditions like extreme vacuum 10-7 [mmHg]. Also this system guarantees the safety of the operating staff.
ACTIFLOW®
Maximum available height h1: mm
Diving depth h2: mm
Connection flange B1 (Min. DN100/ANSI 4"):
Unit DN/Size PN/Class
DN
AINSI
Stainless steel 1.4435/1.4571 with PTFE seals
Hastelloy® 2.4602/HC22 with PTFE seals
Working pressure
Min. Available Max.
2 bar 6 bar
Volume of desired sample: ml
Sampling frequency: / day

Reactor / tank
Connection flange B2:
Unit DN/Size PN/Class
DN
AINSI
Internal diameter d1: mm
Manufacturer:
Type:
Standard:
Volume: m3
Material:
Allowable
temperature:
Min Max °C
°F
Allowable
pressure:
Min Max bar
PSI
Agitator system:
Height: mm Diameter: mm


Characteristics of the product, sampling, analysis Comments
1. Chemical composition: Formula: Name:
2. Temperature of the liquid: Min: °C °F Max: °C °F
3. Solidification temperature of the liquid: °C °F
4. Working pressure: bar lbs
5. Viscosity and vapor pressure of the product in the working area:
Temperature °C °F 20°C / 68°F
Viscosity cP SSU
Vapor pressure mbar psi
6. Toxicity of the product: low high
7. Can the liquid come into contact with the atmosphere? yes no
8. Does the liquid sampled solidify in the receptacle? yes no
Necessary to pre-heat receptacle before filling? yes no
Necessary to re-heat receptacle to empty? yes no
9. How is removed sample used?
emptied into another receptacle
injected using a needle
10. What happens to the remainder of the sample?

Additional note

*Antispam (enter : biarsamplingsystem):

 
BIAR Switzerland
BIAR SA
Rte du Gd-St-Bernard 16
CH-1933 Sembrancher
Tel. +4127 779 11 11
Fax +4127 779 11 12
BIAR USA
BIAR, Inc.
2506 S. Philippe Ave.
Gonzales, LA 70737
Tel: 225-647-4300
Fax: 225-647-4309
This e-mail address is being protected from spambots. You need JavaScript enabled to view it
Copyright © BIAR Sampling Systems. All rights reserved.